Typical Pipe Penetration Procedure
- After installation of pond liner, carefully cut hole to allow pipe to slide through liner. Allow liner to fit flat on ground.
- Slide boot over pipe and push down to pond floor/wall, etc…
- Carefully cut boot flange base so that it exceeds the cut in the liner by 4 to 6 inches in all directions. Make the flange square.
- Clean liner and flange. Use water, MEK, Xylene, etc… Do not use soap.
- Mark a line around flange and remove boot.
- Please note some versions of our tape on boots now come with fully adhesive coated base plates identified by a white peel off layer on the entire bottom of the boot. If applicable please skip step #7 below and proceed to step #8
- Place 2" wide double sided tape on liner (bottom view drawing). Be sure to overlap at corners by 14". Leave film layer on the top of tape. Use a rag to firmly press down the tape and work out any wrinkles.
- Replace boot remove protective covering and press down on the tape and work out wrinkles.
- Place 4" single sided tape completely over edge of boot, centering on the seam.
- Place band clamp on boot riser approximately 1" from top of boot. Tighten and cover with 4" single sided tape.


Weld on pipe boot installation slide show